Weighing Scale
Sartorius
Mettler
Rapid Prototyping
EnvisionTec-RP Machine
Consumables
CAD Software
Jewelcad
Engraving Machine
U-MARQ - U.K.
Precious Metal Analyzer
Hatton Square - UK
Casting Machine
Seit Electtronica - Italy
Ti Research Germany
Akron Rubber
Zero-D-USA
Coniex - Spain
Tools/Files
Bergeon - Switzerland
Shesto Tools-UK
Solitaire -Germany
Alloys
  Pandora Alloy - Italy
Polishing Materials
  Luxi - UK
  Davis -K Rhodium
 
Casting Machine - Seit Electtronica

Inquiry
 


 
VaccumPlus DS2/4
 
 Specifications
- Maximum crucible capacity: 150 g Pt
- Maximum flask dimension: Ø mm 90 x H mm 90
- Medium Frequency Melting Circuit: 40-80 Khz
- Built in 20 m3 vacuum pump – Argon Gas circuit
- Power Supply: 220/230 V – Single Phase
- Maximum Absorbed Power: 4 kW
- Dimensions: L 67 cm – P 55 cm – H 100 cm
- Weight: 150 Kg
 
 
 


 

 
VaccumPlus DS12
 
 Specifications
- Maximum crucible capacity: 200 g Pt
- Maximum flask dimension: Ø mm 90 x H mm 90
- Medium Frequency Melting Circuit: 40-80 Khz
- Built in 20 m3 vacuum pump – Argon Gas circuit
- Power Supply: 220/230 V – Single Phase
- Maximum Absorbed Power: 5 kW
- Dimensions: L 67 cm – P 55 cm – H 100 cm
- Weight: 150 Kg
 
 
 


 

 
SuperCast 12 With patented RCS
 
 Specifications
- Maximum crucible capacity: 150 g Pt
- Maximum flask dimension: Ø mm 90 x H mm 90
- Medium Frequency Melting Circuit: 60-90 Khz
- Built in 20 m3 vacuum pump – Argon Gas circuit
- Power Supply: 220/230 V – Single Phase
- Maximum Absorbed Power: 4 kW
- Dimensions: L 67 cm – P 55 cm – H 100 cm
- Weight: 150 Kg
 
 
 


 

 
SuperCast 13 With patented RCS
 
 Specifications
- Maximum crucible capacity: 200 g Pt
- Maximum flask dimension: Ø mm 90 x H mm 90
- Medium Frequency Melting Circuit: 60-90 Khz
- Built in 20 m3 vacuum pump – Argon Gas circuit
- Power Supply: 220/230 V – Single Phase
- Maximum Absorbed Power: 5 kW
- Dimensions: L 67 cm – P 55 cm – H 100 cm
- Weight: 150 Kg
 
 
 
Features
 
Benefit comparing with other
traditional centrifugal casting machines
  Coil rotating with arm and flask   No more death time due to the coil lift down
  Coil still heating during rotation   Metal injected in liquid fase
  New generation control board   Totally microprocessor controlled
  New generation temperature reader   More accurate temperature reading
  New Hi Tech Thermoregulator   Better heating cycle control
  Metal emissivity regulation   More easy to find the metal melting point
  Autodiagnosys   10 Error messages
  10 Memories   9 parameter per program
  Vacuum-Argon washing cycle   For casting with stone
  80 g Titanium casting   Only in SuperCast 13
 
 
For more details - Click here
 
 
                                 © 2007 sartorius
Website Designed and Maintainted by Cyber Nebula